KROHNE OPTIWAVE 7300 C Handbook page 16

Radar level meter for distance, level and volume measurement of liquids, pastes and solids
Hide thumbs Also See for OPTIWAVE 7300 C:
Table of Contents

Advertisement

Handbook OPTIWAVE 7300 C
Installations with difficult measurement conditions
Agitators, other mixing equipment, filling and emptying cycles can cause foam, vortices and turbulent
product surfaces.
Mounting a device in a bypass chamber or stilling well are ideal solutions for these condtions.
For further information, refer to section 1.3.3: Typical installations; stilling wells and section 1.3.4: Typical
installations; bypass chambers.
Ambient temperature
The ambient temperature limits of the device are given below.
Outdoor installations
Fit a sunshade on the level meter for outdoor installations: this is supplied on demand.
Procedure - fitting a sunshade
1. The sunshade is delivered separately; attached to a metal tube (A) to prevent deformation of the
mounting bracket.
2. Unscrew two M6 socket head cap screws (B) with a 5 mm hexagonal key (C).
OPTIWAVE 7300 C
16