Connectors

Z001 connectors
Power supply voltage 230 Vac
X1
Connector A001
X2
Power supply voltage 230 Vac
X3
Shunt resistor, (-)
X4
Machine body, equipment earth
X5
Aux. transformer T002 supply voltage ~230 Vac
X9
Aux. transformer T002 supply voltage ~230 Vac
X10
Supply voltage to spark generator card A002
X11
Supply voltage to spark generator card A002
X12
Secondary choke L002, (+)
X13
PTC, main transformer
X14
PTC, main transformer
X15
Machine body, equipment earth
X16
X16
C
B
Measuring point A. X1, X3
Measuring point B. X2/6, X2/12
Measuring point C Primary rectifier
X5
X1
X3
X9
A
X10
X2
X12
X11
X13
X14
X15
X4