Figure 90. system management board and backplane assembly installation
Step 2.
Tighten the system management board with 6 6#32 screws.
Step 3.
Tighten the system management board with 2 M3 screws.
Step 4.
Reinstall the cables (see "Internal cable routing and connectors" on page 144).
Step 5.
Reinstall the system management board cover (see "Installing the system management board
cover" on page 85).
Step 6.
Reinstall the fan cage cover (see "Installing the fan cage cover" on page 83).
Step 7.
Reinstall the power supplies (see "Replacing a hot-swap power supply" on page 99).
1. Install the server into the rack enclosure and push the server into the rack until it clicks into place.
2. Reconnect the power cords and any cables that you removed.
3. Turn on the peripheral devices and the server.

Internal cable routing and connectors

This section provides information about routing the cables when you install some components in the server.
Notes:
• Turn off the server and peripheral devices and disconnect the power cords and all external cables before
routing the cables.
• Always match the numbers on the printed circuit boards and the numbers on the cables to connect
the cables.
For more information about the requirements for cables and connecting devices, see the documentation
that comes with these devices.
The following illustration displays the cabling information on the fan board:
144
Lenovo ThinkServer sd350 Server Type 5493, Lenovo ThinkServer n400 Enclosure Type 5495Installation and Service Guide