Appendix B. Diagnostic error messages

Use this information to resolve any issues that were found.
Message
Memory Test Failed
MegaRaid Test Failed
LSI Test Failed
© Copyright Lenovo
Description
Memory Failure was detected.
Raid controller test has detected
an error.
Raid controller test has detected
an error.
Action
1.Please check ECC and error
logs in setup, test reports and
verify ECC indicators on system
board to identify failing module.
ECC circuitry may have recovered
the failing module and further data
is included in the report under
critical error logs for verification
test.
2.Reseat firstly. If it still fails, then,
replace defective module and
contact Lenovo Customer Service
for further support options.
1.Please refer to drive status in
the test results to see if RAID
drives are responding. If no
response, check installed drivers
to see if active. If drive degraded,
one of the raid drives has failed
and needs to be replaced.
2.Make sure all drive carriers
are in place and locked position.
Make sure RAID BIOS settings
are properly set.
3. Replace a raid card.
4. If still fails, please contact
Lenovo Customer Service for
further options.
1.Please refer to drive status in
the test results to see if RAID
drives are responding. If no
response, check installed drivers
to see if active. If drive degraded,
one of the raid drives has failed
and needs to be replaced.
2.Make sure all drive carriers
are in place and locked position.
Make sure RAID BIOS settings
are properly set.
3.Replace a raid card.
4. If still fails, please contact
Lenovo Customer Service for
further options.