Sanken SAMCO-NS Series Instruction Manual page 55

Compact vector control inverter, simple version, vvvf inverter
Table of Contents

Advertisement

Code Function Name
Data Content
3103
PID2 control proportional
0~100
gain
3104
PID2 control integral
0.01~100 sec.
Time
3105
0~100 sec.
PID2 control dividential
Time
PID2 control integral
3106
5~100%
speparation judgement
value
3107
1~500(set value 1=10ms)
PID2 feedback signal
Input filter time constant
3108
Indirect PID2 input
5~100%(Target value reference)
Reference
0:No limit
3109
PID2 deviation limit value
1~100%
0:No limit
3110
PID2 output limit value
1~100%
1:command value-feedback value
3111
PID2 operation polarity
2:feedback value-command value
switching
1: The plus or minus deviation indicates the
3112
PID2 gain polarity
2: The plus or minus deviation indicates the
Switching
3113
PID2 command value
0~50
gain
3114
PID2 Feedback value
0~50
Gain
3115
0~100
PID2 control proportional
gain
(Negative :F3012=2)
3116
PID2 control integral time
0.01~100 sec.
(negative :F3012=2)
3117
PID2 control command
0~6000
Value
PID2 control feedback
3118
0~6000
value(communication
function)
(Upper frequency limit reference)
(Upper frequency limit reference
(Upper frequency limit reference
same gain
different gain
-54-
Setting
Factory
resolution
preset
0.01
0.1
0.01 sec.
1
0.01 sec.
0
0.1%
100
1
10
0.1%
20
0.1%
100
)
0.1%
100
)
1
1
1
1
0.01
1
0.01
1
0.01
0.1
0.01sec.
0.1
0.1
0
0.1
0