Graph Operation Function F21Xx-Fxx - Sanken SAMCO-NS Series Instruction Manual

Compact vector control inverter, simple version, vvvf inverter
Table of Contents

Advertisement

Graph operation function F21xx~Fxx
Graph operation function F21xx~Fxx
Code
Function Name
Data Content
st
2101
1
frequency
0~600Hz
nd
2102
2
frequency
0~600Hz
rd
2103
3
frequency
0~600Hz
th
2104
4
frequency
0~600Hz
th
2105
5
frequency
0~600Hz
th
2106
6
frequency
0~600Hz
th
2107
7
frequency
0~600Hz
th
2108
8
frequency
0~600Hz
th
2109
9
frequency
0~600Hz
th
2110
10
freuqency
0~600Hz
th
2111
11
frequency
0~600Hz
th
2112
12
frequency
0~600Hz
th
2113
13
frequency
0~600Hz
th
2114
14
frequency
0~600Hz
th
2115
15
frequency
0~600Hz
th
2116
16
frequency
0~600Hz
Selection of
0:Normal operation
2201
scheduled operation
1:Simple scheduled operation
2:Disturbed operation
Simple scheduled
0:Continuous
2202
operation repetition
1~250:Repetition count
2203
Operation timer T1
0~65000 sec.
2204
Operation timer T2
0~65000 sec.
2205
Operation timer T3
0~65000 sec.
2206
Operation timer T4
0~65000 sec.
2207
Operation timer T5
0~65000 sec.
2208
Operation timer T6
0~65000 sec.
2209
Operation timer T7
0~65000 sec.
2210
Operation timer T8
0~65000 sec.
2211
Operation timer T9
0~65000 sec.
2212
Operation timer T10 0~65000 sec.
2213
Opertion timer T11
0~65000 sec.
Setting
resolution
0.01Hz
0.01Hz
0.01Hz
0.01Hz
0.01Hz
0.01Hz
0.01Hz
0.01Hz
0.01Hz
0.01Hz
0.01Hz
0.01Hz
0.01Hz
0.01Hz
0.01Hz
0.01Hz
1
1
1sec.
1sec.
1sec.
1sec.
1sec.
1sec.
1sec.
1sec.
1sec.
1sec.
1sec.
-46-
Factory
preset
0
10
20
30
40
50
60
0
0
5
15
25
35
45
55
0
0
1
10
10
10
10
10
10
10
10
10
10
10

Hide quick links: