Sanken SAMCO-NS Series Instruction Manual page 51

Compact vector control inverter, simple version, vvvf inverter
Table of Contents

Advertisement

Code
Function Name
Data Content
nd
1:No unit(Multiple of F1203 )
2304
LCD 's 2
screen
2:Output voltage [V]
display parameters
3:DC voltage[V]
setting
4:Active power [kW]
5:Apparent power [kVA].
6:Radiator temperature [℃]
7:Command speed [rpm]
8:PID1 feedback value [Hz]
9:PID2 feedback value [Hz]
10:VRF analog input value [Hz]
11:V/I analog input value [Hz]
14:Partial execitation current [A]
15:Partial torque current [A]
17:Set pressure[MPa]
18:Command pressure[MPa]
19:Feedback pressure[MPa]
20:Regular pump to switch calculating time
29:Command frequency [Hz]
35:Detection speed [rpm]
44:Target frequency [Hz]
45:Output frequency [Hz]
LCD backlight out
0:off
2306
time
1~600:the time until it goes off
999:Normally on
Setting
resolution
1
1min.
-50-
Factory
preset
2
10

Hide quick links:

Advertisement

Table of Contents
loading