Electronic Control Troubleshooting
29. Will Not Start – Steam – Manual Timer
Single and stacked units with and without
Is there power supply
voltage coming to the
tumbler?
Is there voltage
at the primary side of the
transformer at
terminals 1 and 2?
Is there voltage
at the secondary side of the
transformer at terminal
2 and 3?
Is there voltage
to the output side of the
secondary fuse?
Is there voltage
to the N.O. terminal of the
door switch?
Correct the wiring
between the door
switch and the
secondary fuse
Is there voltage to the
N.O. terminal of the
lint panel switch?
48
time delay boards.
NO
Connect power
and run the cycle.
YES
Change the primary
NO
fuse to the
transformer
YES
NO
Replace the
transformer.
YES
NO
Change the
secondary fuse.
NOTE: White wires are
YES
transformer "neutral"
YES
NO
YES
NO
Replace lint
panel switch.
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Correct wiring
Still no voltage
between power
transformer.
For stacked units.
Correct wiring
between upper and
lower pocket.
Correct the wiring
NO
between the
secondary fuse and
the transformer.
Is there voltage to the
YES
COM terminal of the
door switch?
NO
Replace the
door switch.
Refer to NO
MOTOR RUN
(run circuit) .
supply and
Is there voltage to the
COM terminal of the
lint panel switch?
NO
Correct wiring
between lint panel
switch and door
switch.
T016D
YES
T016D
70291301