NetMaster Troubleshooting
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the tumble dryer before servicing.
• Close gas shut-off valve to gas tumble dryer before servicing.
• Close steam valve to steam tumble dryer before servicing.
• Never start the tumble dryer with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the tumble dryer is properly grounded.

58. No IR Communication

IR Communication
Attempt to
communicate with
the electronic
control from the
microwand.
Is there a response of
any kind from the
electronic control?
YES
Does the electronic
control display E:OF
or -C-?
"E:OF"
Check the following:
- IR communication disabled by
manual programming.
- Is the IR window on the control
covered or blocked.
- if needed, change control
board.
120
Section 7
Single and stacked.
Gas and electric heat.
Single and three phase
power supply.
NO
Aim microwand
closer and try again.
-C-
Communication
sequence checks
out.
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
WARNING
No IR Communication
Does the control
respond?
YES
Check the following:
- low battery on microwand
NO
- is the IR window covered or
blocked on the control.
- if needed replace the electronic
control
- is the IR cap properly attached to
the microwand.
TMB247S
TMB247S
W002R1
70291301