ALLIANCE T30 Series Troubleshooting Manual page 70

Tumble dryers
Hide thumbs Also See for T30 Series:
Table of Contents

Advertisement

Electronic Control Troubleshooting
37. Will Not Run – Steam – Manual Timer (continued)
**
Is there voltage across
terminal 7 & 4 of the
motor control relay?
NO
Is there voltage at
terminal 5 on the
motor control relay to
to supply neutral?
YES
Is there voltage across
terminal 5 & 8 of the
motor control relay?
NO
Is there voltage across
terminals 1 & 4 of
fan motor?
YES
Tested with the start switch pressed in.
**
68
YES
Replace motor
control relay.
Correct wiring
NO
between terminal
5 and supply
voltage.
YES
Replace motor
control relay.
Correct wiring
between fan
NO
motor and contact
8 on the motor
control relay.
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
NO
Does the fan motor
run?
YES
Note: Only for non time
delay machines
Is there
voltage across
terminals 3 & 5 of
YES
the fan motor
centrifugal switch with
the fan motor
running?
NO
Is there voltage to
NO
terminal 6 on the
motor control relay and
supply neutral?
YES
Is there voltage across
YES
terminal 6 & 9 of the
motor control relay?
NO
Is there voltage at
NO
terminals 1 & 4 of
the cylinder motor?
YES
NO
Does the cylinder
motor run?
YES
The cylinder and
fan motors are
operational.
Replace the fan
motor.
Replace fan
motor.
Correct wiring
between terminal
6 and power
supply.
Replace motor
control relay.
Correct wiring
between cylinder
motor and contact
9 on the motor
control relay.
Replace the
cylinder motor.
T018D
T018D
70291301

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents