Changing Heater Control Setting Temperature - Seiko OC CS 6060 IP-6600 User Manual

Solvent ink color inkjet printer
Table of Contents

Advertisement

Changing Heater Control Setting Temperature

Front Heater ON/OFF key
Front Heater UP/DOWN key
2-40
Print Heater ON/OFF key
In normal use, temperatures of all heaters for the every selected
media are preset automatically.
Therefore, ON/OFF setting and temperature setting for all heaters
are not necessary.
Use the heater control panel only when the fine adjustment for the
heater temperature is desired.
Set on/off and setup temperature of three heaters on the heater
control panel.
• ON/OFF setting: Use ON/OFF key for each heater.
• Temperature setting: Use the up key or down key for each heater.
• LCD screen: (When the heater is turned ON)
The preset temperature range is fixed to 15 °C to 55 °C.
Precautions for setting the heater temperature
The heater temperature is preset automatically, but the ON/OFF
setting for all heaters are not preset automatically.
Therefore, in normal use, keep the heaters to the ON state (state
that temperatures are displayed).
LCD
Rear Heater ON/OFF key
Print Heater UP/DOWN key
• Upper line: Preset temperature for each heater
• Lower line: Current temperature for each heater
(When the heater is turned OFF)
• Upper line: "OFF" for each heater
• Lower line: Current temperature for each heater
Preset temperature
Current temperature
Rear Heater UP/DOWN key