Vega VEGAPULS 62 Operating Instructions Manual page 79

Radar sensor for continuous level measurement of liquids
Hide thumbs Also See for VEGAPULS 62:
Table of Contents

Advertisement

Recommended measuring range
Ʋ Antenna ø 40 mm (1.575 in)
Ʋ Antenna ø 48 mm (1.89 in)
Ʋ Antenna ø 75 mm (2.953 in)
Ʋ Antenna ø 95 mm (3.74 in)
Ʋ Parabolic antenna
Output variable
Output signal
Sensor address
Damping (63 % of the input variable)
Profibus PA profile
Number of FBs with AI (function blocks
with analogue input)
Default values
Ʋ 1. FB
Ʋ 2. FB
Ʋ 3. FB
Current value
Ʋ Non-Ex and Ex ia instrument
Ʋ Ex-d-ia instruments
Resolution, digital
Deviation (according to DIN EN 60770-1)
Process reference conditions according to DIN EN 61298-1
Ʋ Temperature
Ʋ Relative humidity
Ʋ Air pressure
Installation reference conditions
Ʋ Min. distance to internal installations
Ʋ Reflector
Ʋ False reflections
Deviation with liquids
Non-repeatability
2)
Deviation with bulk solids
Deviation with bulk solids
Already included in the meas. deviation
2)
VEGAPULS 62 • Profibus PA
up to 15 m (49.21 ft)
up to 20 m (65.62 ft)
up to 40 m (131.23 ft)
up to 50 m (164 ft)
up to 75 m (246.1 ft)
digital output signal, format according to IEEE-754
126 (default setting)
0 ... 999 s, adjustable
3.02
3
Primary Value (filling height linearized in %)
Secondary Value 1 (filling height in %)
Secondary Value 2 (distance value)
10 mA, ±0.5 mA
16 mA, ±0.5 mA
< 1 mm (0.039 in)
+18 ... +30 °C (+64 ... +86 °F)
45 ... 75 %
860 ... 1060 mbar/86 ... 106 kPa (12.5 ... 15.4 psig)
> 200 mm (7.874 in)
Flat plate reflector
Biggest false signal, 20 dB smaller than the useful signal
≤ 2 mm (meas. distance > 0.5 m/1.64 ft)
≤ 1 mm
The values depend to a great extent on the application.
Binding specifications are thus not possible.
The values depend to a great extent on the application.
Binding specifications are thus not possible.
11 Supplement
79