UV Info Screen
Press the "UV Info" button on Main screen to navigate to UV Info screen to read the total number of
hours of UV operation and the number of hours since last cleaning.
It also allows resetting those statistics.
The number of hours since last cleaning has to be reset after each UV lamp cleaning.
If UV lamps are replaced with new ones, both statistics, the total number of hours and since last
cleaning have to be reset.
To reset any of those statistics, press corresponding "Reset" button. This operation is password pro-
tected so a password data entry window will pop up.
Touch "Name" or "Password" field, to enter values. Keypad will popup to let enter data. After done,
press "Ent"