Troubleshooting Power And Com Port Connections - Paradyne FrameSaver SLV 9x24 Series Installation Instructions Manual

1-slot unit
Table of Contents

Advertisement

Troubleshooting Power and COM Port Connections

Symptom
Possible Cause
No power, or none
Power cord is not
of the system LEDs
securely plugged into the
are lit.
wall power outlet or the
universal power supply.
Wall receptacle has no
power.
Power supply is
defective.
An LED is not lit.
LED is burned out.
Power-Up Self-Test
The FrameSaver unit has
fails. The Alarm
detected an internal
LED is on after
hardware failure.
power-up, but the
OK LED is not.
Cannot access the
Login or password is
FrameSaver unit or
incorrect, COM port is
the user interface.
misconfigured, or access
to the FrameSaver unit is
misconfigured.
Solutions
Check that the power cord is
securely attached at both ends.
1. Check the wall receptacle power
by plugging in some equipment
that is known to be working.
2. Check the circuit breaker.
Contact your sales or service
representative for replacement of
the power supply.
Run the Lamp Test. If the LED in
question does not flash with the
other LEDs, contact your sales or
service representative.
1. Reset the FrameSaver unit and
try again.
2. Contact your service
representative.
1. Reset the FrameSaver unit (see
Chapter 12, Operation and
Maintenance , the User's Guide).
2. Contact your service
representative.
6

Advertisement

Table of Contents
loading

This manual is also suitable for:

Framesaver slv 9124Framesaver slv 9624

Table of Contents