Entering Trap Managers

Now that the FrameSaver unit is connected to the network, SNMP Trap Managers can
be configured.
To enter SNMP managers:
1. Select SNMP Traps configuration options.
Main Menu
Configuration
Management and Communication
2. Minimally, enter at least one trap manager – the central site's NMS trap manager:
– SNMP Traps set to Enable.
– Number of Trap Managers
– NMS n IP Address ( n being the first, second, third, etc. trap manager entered)
3. Press Ctrl-a to move the cursor to the bottom of the screen.
4. Type s (Save) and press Enter. The Save Configuration To: prompt appears.
5. Select Current Configuration and press Enter.
6. Press Esc three times to return to the Main Menu.
Helpful Hint:
You can press Ctrl-a, type m and press Enter to return to the Main Menu, or
you can press the Esc key until the Main Menu appears.