Connecting to the DSX (9124 Only)

1. Connect the DB15 end of the DSX cable to the DSX-1 interface.
2. Connect the other end of the cable to the FCC Part 68 Registered CPE (customer
premises equipment, like a PBX).
3. Tighten the screws on each side of the connector to secure them.
POWER
COM
Verification Check:
1. Check the DSX LEDs. Is the Sig (DSX-1 signal) LED on, and are the DSX-1 OOF
(out of frame) and ALM (alarm) LEDs off?
– If yes, the DSX interface is set up correctly and operational.
– If no, check that both ends of the DSX cable are properly seated and secured.
2. Check Health and Status messages in the left column of the System and Test
Status screen to verify that there are no DSX-1 Health and Status messages.
– If any DSX-1 messages appear, refer to the status information in Chapter 11,
Displaying System Information , of the User's Guide.
See Chapter 11, Displaying System Information , of the User's Guide for additional
status information. See Chapter 13, Troubleshooting , for additional troubleshooting
information.
Proceed to Connecting to the DTE on page 19.