Verification Check for a FrameSaver 9124:
1. Check the Network LEDs. Is the Sig (signal) LED on, and are the OOF (out of
frame), and ALM (alarm) LEDs off?
– If yes, the network interface is set up correctly and is operational.
– If no, check that both ends of the network cable are properly seated.
2. Check Health and Status messages in the left column of the System and Test
Status screen to see the LMI status, to verify that LMI is up.
Main Menu
Status
– If LMI Down, Network appears for more than three minutes, or any other
network-related status message appears, refer to the status information in
Chapter 11, Displaying System Information , of the User's Guide for possible
reasons for the messages and what can be done to resolve the problem.
Proceed to Entering Trap Managers on page 14.
Verification Check for a FrameSaver 9624:
1. Is the Network OOF/ NS (out of frame/no signal) and ALM (alarm) LEDs off?
– If yes, the network interface is set up correctly and is operational.
– If no, check that both ends of the network cable are properly seated.
2. Check Health and Status messages in the left column of the System and Test
Status screen to see the LMI status, to verify that LMI is up.
Main Menu
Status
– If LMI Down, Network appears for more than three minutes, or any other
network-related status message appears, refer to the status information in

Chapter 11, Displaying System Information , of the User's Guide.

Proceed to Entering Trap Managers on page 14.