Entering Trap Managers

Now that the FrameSaver unit is connected to the network, SNMP Trap Managers can
be configured.
To enter SNMP managers:
1. Select SNMP Traps configuration options.
Main Menu
SNMP Traps
2. Minimally, enter at least one trap manager – the central site's NMS trap manager:
– SNMP Traps is set to Enable.
– Number of Trap Managers
– NMS n IP Address ( n being the first, second, third, etc. trap manager entered)
– Destination
3. Save the configuration and return to the Configuration Edit/Display menu.

Setting Up Service Provider Connectivity

If management needs to be set up between a service provider's customer and its
network operations center (NOC), a non-multiplexed DLCI must be configured to carry
management data between the customer's central site and the NOC console. This
requires that a frame relay discovered DLCI needs to be modified. This is because all
auto-configured network DLCIs are configured as multiplexed DLCIs.
To set up NOC management:
1. Select DLCI Records on the network interface:
Configuration
2. Select Modify. The Modify DLCI Record for DLCI Number? prompt will appear.
3. Select the DLCI that will be used
number appears, then select it.
4. With the cursor on the DLCI Type field, press the spacebar to change the DLCI
Type from Multiplexed to Standard.
The Delete EDLCI Connections and Make it a Mgmt Only PVC? prompt
appears.
5. Type y for yes and press Enter.
PVC connections for the selected DLCI are broken, the Port-1 DLCI mapped to
this network DLCI and the embedded management DLCI (EDLCI) are deleted, and
the selected DLCI will be reconfigured as a management PVC using the Node IP
Address.
6. Return to the Main Menu.
Configuration
Management and Communication
Network
DLCI Records
by
pressing the spacebar until the correct DLCI
19