Wiring The Fault Alarm Contact - Planet IGTP-802T User Manual

1000base-x to 10/100/1000base-t 802.3at poe industrial media converter
Table of Contents

Advertisement

2. Tighten the wire-clamp screws for preventing the wires from
loosening.
1. The wire gauge for the terminal block should be in
the range between 12 and 24 AWG.
2. The DC power input range is 12V ~ 48V DC and
supports 24V AC.
Note
3. Please just use one power input when using 24V AC.

2.1.6 Wiring the Fault Alarm Contact

The fault alarm contacts are in the middle of the terminal block
connector as the picture shows below. Inserting the wires, the
Industrial 802.3at PoE Media Converter will detect the fault status
of the power failure, and then forms an open circuit. The following
illustration shows an application example for wiring the fault alarm
contacts.
18
1
2
3
Power 1
Fault
+
-
Insert the wires into the fault alarm contacts
4
5
6
Power 2
+
-