2. Tighten the wire-clamp screws for preventing the wires from loos-
ening.
The wire gauge for the terminal block should be in the
range between 12 and 24 AWG.
Note

3.4 Wiring the Fault Alarm Contact

The fault alarm contacts are in the middle of the terminal block
connector as the picture shows below. When inserting the wires, the
Industrial Media Converter will detect the fault status of the power
failure and then forms an open circuit. The following illustration shows
an application example for wiring the fault alarm contacts.
1
Fault Alarm Contacts
Insert the wires into the fault alarm contacts
16
1
2
3
4
Power 1
Fault
+
-
2
3
4
5
Fault
5
6
Power 2
+
-
6
The Fault Alarm Contacts are
energized (CLOSE) for normal
operation and will OPEN when
failure occurs