3. Wiring the Power Inputs
The Upper Panel of the Media Converter comes with one 6-contact
terminal block. Please follow the steps below to insert the power wire.
1. Insert positive/negative DC power wires into Contacts 1 and 2 for
Power 1, or Contacts 5 and 6 for Power 2.
IGT-900-1T1S and IGT-900-2T2S: DC 9-48V, AC 24V
Figure 3-1: IGT-900-1T1S/IGT-900-2T2S Upper Panel
2. Tighten the wire-clamp screws for preventing the wires from loos-
ening.
IGT-900-Series
PWR1 and PWR2 must provide the same DC voltage
while operating with dual power input.
Caution
Max. Fault Alarm Loading: 24V, 1A
1 2 3 4 5 6
V1+
V2+
PWR1
Alarm
PWR2
1
2
3
4
V+ V-
Power 1
Positive (+) Pin
Pin 1/5
DC Input: 9-48V
, 1A max.
AC Input: 24V
, 0.6A max.
5
6
V+ V-
Power 2
Negative (-) Pin
Pin 2/6
5