3. Wiring DC Power Inputs

The 6-contact terminal block connector on the panel of the Industrial Managed
PoE Media Converter is used for two DC redundant power inputs. Follow the
steps below to insert the power wires.
1. Insert positive/negative DC power wires into Contacts 1/2 for Power 1, or
Contacts 5/6 for Power 2.
2. Tighten the wire-clamp screws for preventing the wires from loosening.
Figure 3-2: Power 1 & 2 Pins of Terminal Block Connector
Max. Fault Alarm Loading: 24V, 1A
1 2 3 4 5 6
DC Input:
V1+
12-54V
, 6.5A max.
PWR1
Figure 3-1: IXT-900 PoE Series Upper Panel
1
2
3
V1+ V2+
Power 1
V2+
Alarm
PWR2
4
5
6
V2+
V2-
Power 2
5