Parameter
TX Power
TX Modulation
RX Decoding
Antenna
SIMATIC RF650M mobile reader
Operating Instructions, 04/2015, C79000-G8976-C404-01
Setting options
Default value
500 mW
500 mW
398 mW
316 mW
251 mW
200 mW
158 mW
126 mW
100 mW
79 mW
63 mW
50 mW
40 mW
32 mW
25 mW
20 mW
16 mW
13 mW
10 mW
8 mW
6 mW
PR-ASK
ASK
PR-ASK
Miller-4
FM-0
Miller-2
Miller-4
Miller-8
Auto
Auto
Antenna 1
"RF650M" software
6.7 The functions in the "Settings" menu
Description
The transmit power (TX Power)
essentially decides the size of the
identification range for transpond-
ers.
Modulation method.
This setting should only be
changed by experienced and
trained RFID users.
This setting should only be
changed by experienced and
trained RFID users.
The integrated turnstile antenna
can be set to a fixed polarization. It
is recommended that you leave the
value at "Auto" since with this tran-
sponders in different positions or
dipole directions can be identified.