Siemens SIMATIC RF650M Operating Instructions Manual page 48

Mobile reader
Hide thumbs Also See for SIMATIC RF650M:
Table of Contents

Advertisement

"RF650M" software
6.4 The functions in the "Tag Editor" menu
Options
Lock status
Set Locks
Security
In the "Security" tab, you can assign passwords for transponder access or for killing the
transponder. A "Kill" destroys the entire memory of the transponder so that the transponder
can no longer be identified by an RFID reader and is therefore no longer usable.
Figure 6-9
Table 6- 8
Parameter
Target Tag
Security
Password
Kill the target tag
48
Setting options
Open
Permanently
Writeable
Locked
Permanently
Locked
--
"Security" tab in the "Tag Editor" menu
Parameters of the "Security" tab
Setting options
--
KILL
ACCESS
00000000 ...
FFFFFFFF
--
Default value
Description
Open
The "Lock state" specifies whether
the selected memory are-
as/passwords are open or secured.
Note that permanent changes are
irreversible.
--
Transfers the locks to the selected
target transponder.
Default value
Description
--
EPC ID of the selected target tran-
sponder
KILL
Selection of the password type that
you want to read out or change.
00000000
Input box for the password
--
Destroys the entire memory of the
selected target transponder.
Operating Instructions, 04/2015, C79000-G8976-C404-01
SIMATIC RF650M mobile reader

Advertisement

Table of Contents
loading

Table of Contents