Accessories - Keysight PNA-X Series Configuration Manual

Network analyzer
Hide thumbs Also See for PNA-X Series:
Table of Contents

Advertisement

PNA Family Applications and Options

Accessories

Solid black series name indicates the feature is available on that
series, while gray series name with strikethrough indicates the
feature is not available on that series. For example:
PNA:
Available on PNA Series
PNA:
Not available on PNA Series
Rack mount kit without handles (Option 1CM)
PNA-X
PNA
PNA-L
Adds a rack mount flange kit 1CM042A and a rail kit (E3663AC)
for use without handles.
Rack mount kit with handles (Option 1CP)
PNA-X
PNA
PNA-L
Adds a rack mount flange kit with handles (5063-1555) and a rail
kit (E3663AC) for use with handles.
Pulse I/O adapter (N1966A)
PNA-X
PNA
PNA-L
This adapter enables coaxial connections between the Pulse
I/O D-sub connector on the rear panel of the analyzer and the
coaxial inputs and outputs of external pulse generators and
external pulse modulators. Coaxial connectors are SMB-male.
The PULSE IN connectors are for controlling the analyzer's
internal IF gates, which are enabled with S93026B/A and used
with narrowband detection. The PULSE OUT connectors are
from the four internal pulse generators, which are enabled
with S93025/26B/A. The PULSE SYNC IN connector is used to
synchronize the internal pulse generators with an external timing
pulse. The RF PULSE MOD IN connector controls the internal
pulse modulator(s) which are enabled with Options 021 and 022.
Pulse I/O adapter (N1966A) simplifies connections
Find us at www.keysight.com
(continued)
Comb Generators
U9391C 10 MHz to 26.5 GHz
U9391F 10 MHz to 50 GHz
U9391G 10 MHz to 67 GHz
PNA-X
PNA
The U9391C/F/G provides precision phase calibration, traceable
to the National Institute of Standards and Technology (NIST)
standard. It is used for nonlinear measurements with the PNA-X
nonlinear vector network analyzer (NVNA). NVNA requires two
comb generators, one is connected during measurements and
another is used only during calibration. A comb generator is also
used to characterize the VNA receivers for delay measurements
of frequency converters using PNA-X or PNA instruments and the
SMC+Phase measurement class (part of S93083B/A).
CalPod calibration refresh modules (8553xB/4xA)
PNA-X
PNA
CalPod calibration refresh modules allow in-situ calibration
refreshes to be performed at the push of a button without
removing the DUT or re-connecting calibration standards.
CalPods are designed for any measurement situation where it
is desirable to ensure that a valid calibration is present before
recording measurement data. For example, they are useful for
removing environmental effects such as cable movement and
thermal-based changes of cables, connectors, and adapters, as
well as connector and switch-matrix repeatability errors. The
modules are especially useful in temperature, or thermal-vacuum
chamber testing. CalPod modules are equipped with 2.92 mm
connectors.
– 85530B 20 GHz ambient-temperature CalPod
– 85531B 20 GHz temperature-compensated CalPod
– 85532B 20 GHz thermal-vacuum compatible CalPod
– 85540A 40 GHz ambient-temperature CalPod
– 85541A 40 GHz temperature-compensated CalPod
– 85542A 40 GHz thermal-vacuum compatible CalPod
– 85523B CalPod controller (provides control for up to
4 CalPods)
– 85556A CalPod drive-cable splitter (allows control for up to
12 CalPods)
– 85554A CalPod drive cable extension (10-meter cascadable
extension cable)
PNA-L
PNA-L