  • Page 1 Keysight Add Configurable Test Set and Source Attenuators Upgrade Kit To Upgrade PNA N5231A/B, N5232A/B, or N5239A/B Option 200 to Option 216 Upgrade Kit Order Numbers: N5231AU-216, N5232AU-216, N5239AU-216, N5231BU-216, N5232BU-216, and N5239BU-216 Keysight Kit Number: N5232-60101 Installation Note...
  • Page 2: Safety Notices

    DOCUMENT OR ANY INFORMATION reproduce, release, perform, CONTAINED HEREIN. SHOULD display, or disclose commercial KEYSIGHT AND THE USER HAVE A computer software or SEPARATE WRITTEN AGREEMENT commercial computer software WITH WARRANTY TERMS COVERING THE MATERIAL IN THIS...
  • Page 3 — 60 dB source step attenuators with brackets and wire harnesses — front panel jumpers — cable guards for front panel jumpers — front panel overlay replacement — new cables After installation of this upgrade, your analyzer will be an N5231A/B Option 216, N5232A/B Option 216, or N5239A/B Option 216.
  • Page 4: Getting Assistance From Keysight

    Getting Assistance from Keysight Installing this upgrade kit requires special skills and experience. If you think you may not be qualified to do the work, or need advice, contact Keysight. Contacting Keysight Assistance with test and measurements needs and information on finding a local Keysight office are available on the Web at: http://www.keysight.com/find/assist...
  • Page 5: Getting Prepared

    Getting Prepared Getting Prepared The PNA contains extremely sensitive components that can be ruined if mishandled. Follow instructions carefully when making cable connections, especially wire harness connections. The person performing the work accepts responsibility for the full cost of the repair or replacement of damaged components. To successfully install this upgrade kit, you will need the following: —...
  • Page 6 The enclosed Software Entitlement Certificate is a receipt, verifying that you have purchased a licensed option for the PNA of your choice. You must now use a Keysight Web page to request a license key for the instrument that will receive the option.
  • Page 7 Getting Prepared Using the information just gathered, you must request license key(s) for your A model or for your B models, a license key file(s) from the Keysight Software Manager: http://www.keysight.com/find/softwaremanager. You will need to provide an email address, Keysight will promptly email your A model license key(s) or a for a B model, license key file(s) attachment message.
  • Page 8: Tools Required For The Installation

    Torque these connections to 21 in-lb. About Installing the Upgrade Products affected N5231A/B, N5232A/B, and N5239A/B Option 200 Installation to be performed by Keysight service center or personnel qualified by Keysight...
  • Page 9 Items Included in the Upgrade Kit Items Included in the Upgrade Kit Check the contents of your kit against the following list. If any part is missing or damaged, contact Keysight Technologies. Refer to “Getting Assistance from Keysight” on page...
  • Page 10 Items Included in the Upgrade Kit Table 1 Contents of Upgrade Kit N5232-60101 Description Part Number Desig. RF cable, A24 mixer brick to REF 1 RCVR R1 IN N5232-20031 RF cable, A24 mixer brick to REF 2 RCVR R2 IN N5232-20024 RF cable, A24 mixer brick to PORT 2 RCVR B IN N5232-20023...
  • Page 11: Overview Of The Installation Procedure

    Installation Procedure for the Upgrade Installation Procedure for the Upgrade The network analyzer must be in proper working condition prior to installing this option. Any necessary repairs must be made before proceeding with this installation. This installation requires the removal of the analyzer’s protective outer covers.
  • Page 12 If the model number, serial number, or option number do not match those on your license key (A models) or license key file (B models), you will not be able to install the option. If this is the case, contact Keysight for assistance before beginning the installation of this upgrade. Refer to “Contacting Keysight”...
  • Page 13 Installation Procedure for the Upgrade Step 5. Remove Some Existing Cables Leave the gray flexible cables, the wire harnesses, and the ribbon cables connected where possible. Any that are removed should be labeled for reconnection later. Be careful not to damage the center pins of the semirigid cables. Some flexing of the cables may be necessary but do not over-bend them.
  • Page 14 Installation Procedure for the Upgrade Figure 1 Source Attenuator Assembly Step 7. Install the A29 and A30 Source Attenuator Assemblies Refer to Figure 2 for this step of the procedure. New parts are listed in Table 1 on page 1. Install both source attenuator assemblies to the deck as shown, using two screws (0515-0372) with each assembly.
  • Page 15 Installation Procedure for the Upgrade Step 8. Install the Cables Follow instructions carefully when making cable connections, especially wire harness connections. Incorrect connections can destroy components, resulting in additional customer costs. Be careful not to damage the center pins of the semirigid cables. Some flexing of the cables may be necessary but do not over-bend them.
  • Page 16 Installation Procedure for the Upgrade Figure 3 Location of Cable Clamps to Secure W19, W22, and W23 — W19 (N5232-20025) A21 MASSY to REF 2 SOURCE OUT * As shown in Figure 3, install two cable clamps (part number 1400-1334) to secure W19 (part number N5232-20025).
  • Page 17 Installation Procedure for the Upgrade — W16 (N5232-20021) A26 test port 2 bridge coupler (thru) to PORT 2 CPLR THRU — W14 (N5232-20020) A30 test port 2 source attenuator to PORT 2 SOURCE — W2 (reuse) (N5232-20082) A21 MASSY to test set deck cable bracket —...
  • Page 18 Installation Procedure for the Upgrade Install the Wire Harnesses To see an image showing the location of these wire harnesses, click the Chapter 6 bookmarks “Bottom Ribbon Cables and Wire Harnesses, 2-Port, Option 216” in the PDF Service Guide . New parts are listed in Table 1 on page If not already done, connect these wire harnesses:...
  • Page 19 Installation Procedure for the Upgrade Figure 5 Lower Front Panel Overlay Replacement Installation Note N5232-90101...
  • Page 20 Installation Procedure for the Upgrade Step 11. Reinstall Front Panel Assembly Refer to Figure 6 for this step of the procedure. Figure 6 Front Panel Assembly Installation Installation Note N5232-90101...
  • Page 21 Installation Procedure for the Upgrade Step 12. Install the New Lower Front Panel Overlay Refer to Figure 5 on page 19 for this step of the procedure. Although a 4-port PNA is shown in the graphic, the concept is the same for the 2-port PNA. New parts are listed in Table 1 on page 1.
  • Page 22 Installation Procedure for the Upgrade Step 13. Install Front Panel Jumpers As shown in Figure 7, install 6 front panel jumper cables (part number N5222-20091). Torque to 10 in-lbs. Figure 7 Front Panel Jumper Cables Installation Step 14. Reinstall the Inner Cover For instructions, click the Chapter 7 bookmark “Removing the Covers”...
  • Page 23 — The analyzer must be powered up and operating to perform this procedure. — The Network Analyzer program must not be running. — Refer to the license message you received from Keysight: Verify that the analyzer’s model and serial numbers match those on the license message you received from Keysight.
  • Page 24 3. In the Select Desired Option list, click 216 - Configurable Test Set. 4. Using the keyboard, enter the license key in the box provided. The license key is printed on the license message you received from Keysight. Enter this key exactly as it is printed on the message.
  • Page 25 So, N5242B-422 is to be deleted from the text file.) Figure 8 Editing a Keysight License File Using a Text Editor. Note: This figure may not contain your specific features and is an example only. In this example N5242B-422 is the incorrect feature. N5242B-423 is the correct feature.
  • Page 26 — Press Help > About NA and verify that Option 216 is listed in the PNA application. 3. After successful installation of all upgrades, some features require some adjustments to ensure the instrument meets its specified performance. Refer to the following Web site: http://na.support.keysight.com/pna. Installation Note N5232-90101...
  • Page 27 PDF Service Guide If you experience difficulty with the basic functioning of the analyzer, contact Keysight. Refer to “Contacting Keysight” on page Calibration Although the analyzer functions, its performance relative to its specifications has not been verified. It is recommended that a full instrument calibration be performed using the analyzer’s internal performance test software.
  • Page 28 Installation Procedure for the Upgrade Step 19. Prepare the PNA for the User 1. If necessary, reinstall front jumper cables. 2. Install the cable guards, pushing them over the front jumper cables until the cushioning material touches the front panel of the PNA. 3.
  • Page 29 Installation Note Xxxxx-xxxxx...