Main Battery Measurement; Multiplexer Relay - Geokon LC-2x4 Instruction Manual

4 channel vw datalogger
Table of Contents

Advertisement

42
A.9 Main Battery Measurement
3V Battery:
Range:
0 to 7.5 VDC
Accuracy:
±1.83mV
Resolution:
0.01 VDC
A.10 Multiplexer Relay
NAIS TXS2SA-4.5V
Contact resistance:
Switching current:
12V Battery:
Range:
Accuracy:
0.1 ohm (max)
1A (max)
0 to 15 VDC
±3.662mV