Appendix A. Specifications; Model 8600-2 Datalogger; Cr6 Measurement And Control Module; Model 8032 Multiplexer - Geokon 8600-2 Instruction Manual

Micro-6000 multi-channel datalogger
Table of Contents

Advertisement

APPENDIX A. SPECIFICATIONS

A.1 Model 8600-2 Datalogger
Analog Inputs
Analog Outputs
Accuracy
Resolution
Static Frequency-Analyzed Vibrating Wire
Accuracy
Resolution
Thermistor Accuracy
Temperature Range
Battery
LxWxH
A.2 CR6 Measurement and Control Module
Please refer to Campbell Scientifics Specification for the CR6 Datalogger
https://s.campbellsci.com/documents/us/product-brochures/s_cr6.pdf
A.3 Model 8032 Multiplexer
Please refer to the Geokon Model 8032 Multiplexer Manual.
http://www.geokon.com/content/manuals/8032_Terminal_Board_and_Multiplexer.pdf
12 single-ended or 6 differential with ±5000
mV, ±1000 mV, ±200 mV ranges 24 bit ADC
±2.5 V or ±2.5 mA ranges 12 bit DAC
±(0.04% of reading + 2 microvolts), 0-40 °C
50 mV (±200 mV range, differential
measurement, input reversal, 5 Hz f
12 V p-p 100-6000 Hz (Spectral analysis
technique)
±0.013% of reading
0.001 Hz RMS
±0.25% of reading
-40 to +80 °C
12 V, 7 Ah Gel Cell
502 x 461 x 263 mm

Table 1 - 8600-2 Specifications

7
)
N1

Advertisement

Table of Contents
loading

This manual is also suitable for:

8600-1

Table of Contents