PAR Z120/ZP120 RGBW
The unit should be mounted using a mounting clamp (not provided), affixing it to the
mounting bracket that is provided with the unit. Always ensure that the unit is firmly
fixed to avoid vibration and slipping while operating. Always ensure that the structure
to which you are attaching the unit is secure and is able to support a weight of 10
times the unit's weight. Also, always use a safety cable that can hold 12 times the
weight of the unit when installing the fixture. It is recommended that a professional
installs the equipment and it must be installed in a place where it is out of the reach of
people's grasp in the height of 0 to 30m.
PAR Z120/ZP120 RGBW
 
Connect the fixtures together in a "daisy chain" by c o n n e c t i n g a XLR cable from
the output of one fixture to the input of the next fixture. The DMX output and input
connectors are pass‐through to maintain the DMX circuit when the power to one of
the units is disconnected. At the last fixture, use a line terminator (see DMX Set Up on
page 9). Each lighting fixture needs to have an address set to receive the data sent by
the controller. The address number is between 0‐511 (usually 0 & 1 are equal to 1). The
maximum number of fixtures that can be connected on one power cable is 15 fixtures
at 120V or 24 fixtures at 240V (including the first fixture).
Note: Use caution when power linking other fixtures to the PAR Z120/ZP120 RGBW as the
power consumption of other lighting fixtures will vary. The X L R cable cannot be
branched or split to a "Y" cable. Inadequate or damaged cables, soldered joints or
corroded connectors can easily distort the signal and shut down the system.
PAR Z120/ZP120 RGBW
Unplug the unit from any power source it may be connected to. Once the power has
been disconnected, use a Phillips-head screwdriver to unscrew the fuse holder located
above the powerCON input. Remove the bad fuse and replace with a new one, and
screw the fuse holder back in.
ADJ Products, LLC Ÿ ww.adj.com
Ÿ
 
PAR Z120/ZP120 RGBW User Instructions Page 20

Installation

Multiple Unit Power Linking
Fuse Replacement