  • Page 1 User Instructions A.D.J. Supply Europe B.V. Junostraat 2 6468 EW Kerkrade The Netherlands www.adj.eu...
  • Page 2 ©2018 ADJ Products, LLC all rights reserved. Information, specifications, diagrams, images, and instructions herein are subject to change without notice. ADJ Products, LLC logo and identifying product names and numbers herein are trademarks of ADJ Products, LLC. Copyright protection claimed includes all forms and matters of copyrightable materials and information now allowed by statutory or judicial law or hereinafter granted.
  • Page 3: Table Of Contents

    ROHS - A great Contribution to the Conservation of Environment ..................16 WEEE – Waste of Electrical and Electronic Equipment ......................17 NOTES ....................................18 NOTES ..........................Fehler! Textmarke nicht definiert. A.D.J. Supply Europe B.V. – www.adj.eu – Par Z100 5K Instruction Manual Page 3...
  • Page 4: General Information

    INOZIONE GENERAL INFORMATION Unpacking: Thank you for purchasing the Par Z100 5K by ADJ Products, LLC. Every Par Z100 5K has been thoroughly tested and has been shipped in perfect operating condition. Carefully check the shipping carton for damage that may have occurred during shipping. If the carton appears to be damaged, carefully inspect your fixture for any damage and be sure all equipment necessary to operate the unit has arrived intact.
  • Page 5: Safety Precautions

    B. The appliance has been exposed to rain or water. C. The appliance does not appear to operate normally or exhibits a marked change in performance. A.D.J. Supply Europe B.V. – www.adj.eu – Par Z100 5K Instruction Manual Page 5...
  • Page 6: Dmx Set Up

    DMX SET UP Power Supply: The ADJ Par Z100 5K contains an automatic voltage switch, which will auto sense the voltage when it is plugged into the power source. With this switch there is no need to worry about the correct power voltage, this unit can be plugged in anywhere.
  • Page 7 2 and 3 of a male XLR connector (DATA + and DATA -). This unit is inserted in the female XLR connector of the last unit in your daisy chain to terminate the line. Using a cable terminator (ADJ part number Z-DMX/T) will decrease the possibilities of erratic behavior.
  • Page 8: System Menu

    DMX 512 Address Channel Mode DMX State Dimmer Mode Dimming frequency Gamma correction Display inversion Manual mode Test Temperature Fixture Hours Software Version Restore factory settings A.D.J. Supply Europe B.V. – www.adj.eu – Par Z100 5K Instruction Manual Page 8...
  • Page 9 2. Use the UP or DOWN buttons to adjust the dimming frequency between 900hz, 1000hz, 1100hz, 1200hz, 1300hz,1400hz, 1500hz, 2500hz, 4000hz, 5000hz, 10000hz, 15000hz,20000hz, or 250000hz. 3. Once you have found your desired dimming frequency press ENTER to confirm. A.D.J. Supply Europe B.V. – www.adj.eu – Par Z100 5K Instruction Manual Page 9...
  • Page 10 - Use this function to display the Software version of the unit. 1. Press the either the MENU button until is displayed, press ENTER. 2. The display will show the software version. A.D.J. Supply Europe B.V. – www.adj.eu – Par Z100 5K Instruction Manual Page 10...
  • Page 11: Dmx Operation

    A DMX controller allows you to create unique programs tailored to your individual needs. 1. The Par Z100 5K has 4 DMX channel modes; 1 channel mode, 2 channel mode, 3 channel mode, and 4 channel mode. See page 12 for a detailed description of the DMX values and traits.
  • Page 12: Channel Mode

    41 - 60 Dimmer 61 - 80 Architectural curves 81 - 100 Theatre 101 - 120 Stage 2 121 - 255 Default to dimmer curve setting A.D.J. Supply Europe B.V. – www.adj.eu – Par Z100 5K Instruction Manual Page 12...
  • Page 13: Dimmer Curve Chart

    Standard (default) Stage 1100 1540 1660 1180 1520 1860 1940 Architectural 1380 1730 2040 2120 Theatre 1580 1940 2230 2280 Stage 2 1100 1660 DIMENSIONAL DRAWINGS A.D.J. Supply Europe B.V. – www.adj.eu – Par Z100 5K Instruction Manual Page 13...
  • Page 14: Installation

    The quantity that can be connected is 15 fixtures maximum @ 120V and 25 fixtures maximum @ 230V. After maximum fixtures is met you will need to use a new power outlet. NOTE: USE CAUTION WHEN POWER LINKING OTHER FIXTURES TO THE PAR Z100 5K AS THE POWER CONSUMPTION OF OTHER LIGHTING FIXTURES WILL VARY! FUSE REPLACEMENT Unplug the unit from any power source it may be connected to.
  • Page 15: Specifications

    Auto Sensing Voltage: This fixture contains an automatic voltage switch, which will auto sense the voltage when it is plugged into the power source. A.D.J. Supply Europe B.V. – www.adj.eu – Par Z100 5K Instruction Manual Page 15...
  • Page 16: Rohs - A Great Contribution To The Conservation Of Environment

    The ROHS directive is an important step to the protection of our environment. We, as manufactures, feel obligated to make our contribution in this respect. A.D.J. Supply Europe B.V. – www.adj.eu – Par Z100 5K Instruction Manual Page 16...
  • Page 17: Weee - Waste Of Electrical And Electronic Equipment

    We are happy to answer any of your inquiries and welcome your suggestions at: info@americandj.eu A.D.J. Supply Europe B.V. – www.adj.eu – Par Z100 5K Instruction Manual Page 17...