Section 5. Programming Reference
Special Notes
Page 5-116
1. Commas must be used to separate the parameters. If a parameter
is omitted between two commas, the default Non-Standard
Protocol Command codes for that parameter will be used. See
Appendix E.
2. This command must be sent as an independent data stream
immediately following the <ESC>A Start code and immediately
preceding the <ESC>Z Stop code. No other commands can be
included in the data stream.
3. If more or less than nine commas are included in the command,
the entire command sequence will be ignored. The command
must contain exactly nine commas.
4. If two characters are specified for a parameter, it will be
interpreted as a hex value. For example:
Command Parameter
2B
+
If a combination of characters are outside the hexadecimal range,
the entire command sequence will be ignored.
5. Downloading Auto Online and Zero Slash settings will overwrite
the values selected using the LCD panel. If these settings are
changed using the LCD panel, they will overwrite any previously
downloaded settings.
PN 9001074 Preliminary
Resulting Command Code
+
+