You can check the cabling with the aid of test mode. Test mode only
works for finger scanners.
A test can only take place if no administrator fingers have been stored
and no mobile device has been coupled.
Connect the mains supply and perform the test within 10 minutes. If 10
minutes have elapsed, the mains supply will have to be reconnected in
order to conduct this test.
Step
Action
1st
2nd
The relay switches.
This means that you can keep your finger on the sensor for up to 5 sec. If
the finger is kept on the sensor for longer than this, the relay will not
switch.
NOTICE
Description
Place a finger on the
sensor and leave it there
for longer than 3 sec.
Remove the finger from
the sensor within the next
2 sec.
NOTICE
Display
The status LED
flashes blue.
The status LED
on the finger
scanner lights up
green. The top
status LED on
the ekey home
CP mini 1 or
ekey home CP
mini 2 lights up
green and the
LED on the ekey
home CP micro 1
lights up green.
Performing
test mode
en│17