Roughing-in Dimensions
Fig. 1
389 mm x 265 mm
(15-5/16" X 10-3/8")
ROUGH OPENING FOR BOX
280 mm
(11")
*
*
-C-L-
152 mm
(6
) MIN.
"
*Note: The Critical Line (-C-L-) on Vacuum
Breaker must typically be 6
above fixture. Consult Codes for details.
RECOMMENDED TOOLS; Fig. 2.
1. Teflon Tape
2. Flat Blade Screwdriver
3. Adjustable Wrench
4. Tape Measure
5. Hacksaw
6. Tubing Cutter
7. File
8. For Sweat Connection; Solder and Torch
9. 2.5mm Hex Wrench
10. 1.5mm Hex Wrench
PRIOR TO INSTALLATION
Note: Prior to installing the Selectronic™Flush
Valve the following items must be installed.
1. Urinal
2. Drain line
3. Water supply line
IMPORTANT:
• All plumbing and electrical wiring should be
installed in accordance with applicable codes
and regulations.
• The use of water hammer arrestors is strongly
recommended for commercial applications. All piping
behind the walls should be properly secured and
fastened.
• Water supply lines must be sized to provide an
adequate volume of water for each fixture.
404 mm
(15-7/8")
SENSOR
OVERRIDE
BUTTON
SUPPLY
SUPPLY
(3/4) NPT.
(3/4
) NPT.
"
-C-L-
-C-L-
108 mm-134 mm
(4-1/4
TO 5-1/4
)
"
"
32 mm
(1-1/4
) DIA.
"
203 mm MAX.
TOP OF
(8
) MAX.
"
FIXTURE
"
(152mm) min.
25 mm (1") MAX.
WALL THICKNESS
FINISHED WALL
15˚
15˚
DETECTION ZONE
400 mm-800 mm
(Factory Setting: 400 mm)
TOP SPUD
FIXTURES
63 mm
(2-1/2
) DIA.
"
120 mm MAX.
(4-3/4
TOP OF
FIXTURE
Fig. 2
2
1
4
5
7
• Flush all water lines prior to operation (see Step 3).
Dirt and debris can cause flush valve to run continuously.
• With the exception of Stop Valve Inlet, DO NOT
use pipe sealant or plumbing grease on any
valve component or coupling!
• Protect the chrome or special finish on the Flushometer.
DO NOT USE toothed tools on finished surfaces to install
or service these valves. Also see "Care and Cleaning"
section of this manual.
• This product contains mechanical and/or electrical
components that are subject to normal wear. These
components should be checked on a regular basis and
replaced as needed to maintain the valve's performance.
3

GENERAL DESCRIPTION:

SELECTRONIC
PROXIMITY URINAL
®
FLUSH VALVE
Concealed Flushometer for 3/4"
Spud Fixtures
CAUTION: Use only American Standard
supplied transformers and cable sets.
Using non-AS supplied cables, or cutting,
splicing or modifying any components will
void the warranty.
BACK SPUD
FIXTURES
203 mm MAX.
176mm MAX.
(8
) MAX.
"
(6-15/16
) MAX.
"
TOP OF
FIXTURE
) MAX.
"
32 mm
(1-1/4
FOR LOCATION OF INLET SUPPLY
ON BACK INLET FIXTURES AND CORRECT
HEIGHT FROM FINISHED FLOOR,
REFER TO FIXTURE INSTRUCTION SHEET.
3
10'
6
9
10
M965643 Rev. 1.6 (11/16)
176 mm MAX.
(6-15/16
) MAX.
"
*
*
-C-L-
152 mm
(6
"
) MIN.
) DIA.
"