Download Print this page

American Standard Selectronic 606B.X10 Installation Instructions Manual page 5

Proximity concealed urinal flush valve

Advertisement

INSTALL VACUUM BREAKER AND
4
FLUSH CONNECTIONS; Fig. 6
. Place the SPUD FLANGE (1) over the spud on the Fixture.
1
Fig. 6.
2. Place FRICTION WASHER (3) and SEAL WASHER (4) inside
SPUD COUPLING NUT (2) and thread onto Spud. Do not
tighten fully. Fig. 6.
3. Remove the ELBOW COUPLING NUTS (6, 6a) from the
CHROME ELBOW (5). Make sure there are a RUBBER (7), &
FIBER GASKET (8) in each. Fig. 6a.
4. With the flange end up, slide the FIBER GASKET (8) and
ELBOW COUPLING NUT (6) onto the VERTICAL OUTLET
PIPE (9). Place the RUBBER GASKET (7) onto the flange.
Now connect the ELBOW COUPLING NUT (6) to the
CHROME ELBOW (5) and tighten fully.
5. Insert the VERTICAL OUTLET PIPE (9) with CHROME ELBOW
(5) assembly into the SPUD COUPLING NUT (2) and push it
down. Do not tighten fully. Fig. 6a.
Note: Cutting the VERTICAL OUTLET PIPE (10) may be nec-
essary for the CHROME ELBOW (5) center line to line up with
opening in the wall.
6. Measure and cut the HORIZONTAL OUTLET PIPE (10) to length
required. Fig. 6b.
Important: Make sure that there is a minimum of 1-1/4" for
engagement with coupling when making your measurement.
7. With the flange end toward the BRASS ELBOW (11) slide the
FIBER GASKET (12) and ELBOW COUPLING NUT (13) onto the
HORIZONTAL OUTLET PIPE (10). Place the RUBBER GASKET
(14) between the flange and the BRASS ELBOW (11) and fully
tighten. Fig. 6b.
8. From behind the wall, insert the assembled BRASS ELBOW and
HORIZONTAL OUTLET PIPE (11, 10) through the hole in the
wall. Install WALL ESCUTCHEON (15) onto the HORIZONTAL
OUTLET PIPE (10). Slide the ELBOW COUPLING NUT (6a)
and TAPERED RUBBER WASHER (7a) onto the HORIZONTAL
OUTLET PIPE (10). Push the HORIZONTAL OUTLET PIPE (10)
into the CHROME
ELBOW (5). Tighten ELBOW COUPLING NUT (6a) but not fully.
Fig. 6b.
9. For back spud installations: Follow steps #1 and #2 to install
the spud coupling kit. Push the HORIZONTAL OUTLET PIPE
(10) into the spud connection on the back of the fixture. Do not
tighten fully. Fig. 6b.
10. All installations: If required, cut VACUUM BREAKER PIPE
(17), leave a minimum of 1-1/4" (32mm) of pipe to ensure
engagement with compression coupling. Assemble the ELBOW
COUPLING NUT (13a) and TAPERED RUBBER WASHER
(14a) onto the VACUUM BREAKER PIPE (17). Install VACUUM
BREAKER PIPE (17) into BRASS ELBOW (11) and hand
tighten ELBOW COUPLING NUT (13a). Fig. 6c.
Note: If cutting VACUUM BREAKER PIPE (17) to size, note
that Critical Line (C/L) on Vacuum Breaker must typically
be 6" (152mm) above fixture. Consult Code for details.
Fig. 6
2
3
1
Fig. 6a
6a
8a
Fig. 6b
11
FLANGE END
BACK SPUD
INSTALLATION
Fig. 6c
19
5
4
3/4" TOP SPUD
7a
5
7
FLANGE END UP
8
6
9
2
14
10
6a
7a
12
13 15
10
BACK SPUD
INSTALLATION
17
13a
TAPERED SIDE UP
14a
TAPERED
SIDE UP
11
TOP SPUD
INSTALLATION
M965643 Rev. 1.6 (11/16)
TOP SPUD
INSTALLATION