Fig. 1
Roughing-in Dimensions
Right or Left Hand Installation
See (Section 5) for converting Flush
Valve to Left Hand Installation.
MANUAL
OVERRIDE
BUTTON
292 mm
(11-1/2")
*Note: The Critical Line (-C-L-) on Vacuum
Breaker must typically be 6
fixture. Consult Codes for details.
RECOMMENDED TOOLS; Fig. 2.
1. Teflon Tape
2. Flat Blade Screwdriver
3. Adjustable Wrench
4. Tape Measure
5. Hacksaw
6. Tubing Cutter
7. File
8. For Sweat Connection; Solder and Torch
9. 2.5 mm Hex Wrench
10. 1.5 mm Hex Wrench
MANUAL
OVERRIDE
BUTTON
PRIOR TO INSTALLATION
Note: Prior to installing the Selectronic™Flush
Valve the following items must be installed.
1. Urinal
2. Drain line
292 mm
3. Water supply line
(11-1/2")
IMPORTANT:
• All plumbing and electrical wiring should be
installed in accordance with applicable codes
and regulations.
• The use of water hammer arrestors is strongly
*Note: The Critical Line (-C-L-) on Vacuum
recommended for commercial applications. All piping
Breaker must typically be 6
behind the walls should be properly secured and
fixture. Consult Codes for details.
fastened.
• Water supply lines must be sized to provide an
adequate volume of water for each fixture.
Fig. 1
73 mm
(2-7/8")
127 mm
(5")
L-C-
108-134 mm
(4-1/4" TO 5-1/4")
*-C-L-
152 mm MIN.
(6") MIN.
FOR 3/4" TOP
SPUD FIXTURES
"
(152 mm) above
73 mm
(2-7/8")
114 mm
(4-1/2")
L-C-
108-134 mm
(4-1/4" TO 5-1/4")
*-C-L-
152 mm MIN.
(6") MIN.
FOR 3/4" TOP
SPUD FIXTURES
"
(152 mm) above

GENERAL DESCRIPTION:

SELECTRONIC™ PROXIMITY URINAL FLUSH VALVE
Exposed Flushometer for 3/4" Top Spud Fixtures
FINISHED WALL
(1" NPT)
419 mm
(16-1/2")
76mm MAX.
(3) MAX.
Fig. 2
2
1
4
FINISHED WALL
5
7
• Flush all water lines prior to operation (See Step 4).
Dirt and debris can cause flush valve to run continuously.
(1" NPT)
• With the exception of Stop Valve Inlet, DO NOT
406 mm
(16")
use pipe sealant or plumbing grease on any
valve component or coupling!
76mm MAX.
• Protect the chrome or special finish on the Flushometer.
(3) MAX.
DO NOT USE toothed tools on finished surfaces to install
or service these valves. Also see "Care and Cleaning"
section of this manual.
• This product contains mechanical and/or electrical
components that are subject to normal wear. These
components should be checked on a regular basis and
replaced as needed to maintain the valve's performance.
3
15˚
DETECTION ZONE
400 -800 mm
(15-3/4 TO 31-1/2)
3
10'
6
8
DETECTION ZONE
400 -800 mm
(15-3/4 TO 31-1/2)
9
10
15˚
M965840 Rev. 2.2 (6/21)