Download Print this page

American Standard Selectronic 606B.X10 Installation Instructions Manual page 4

Proximity concealed urinal flush valve

Advertisement

FLUSH VALVE INSTALLATION
INSTALL ELECTRICAL BOX; Fig. 3
1
1. Frame out a 389mm x 265mm (15-5/4" X 10-3/8") rough
opening in wall for the WALL BOX (1) at the dimension
shown.
2. Fasten one end of the SAFETY CHAIN (2) and CLIP
(4) to the WALL BOX (1) with NUT & SCREW (3) provided.
3. Install the WALL BOX (1) into rough opening in the wall
Level and secure the WALL BOX (1) to the wall opening
with screws.
Important: Front face of WALL BOX (1) should be flush
with finished wall.
4. Cut a 2" hole for outlet pipe to fixture at dimension shown.*
2
INSTALL SWEAT ADAPTER; Fig. 4
Turn water supplies off before
CAUTION
beginning
Note: Stop Valve inlet is 3/4" NPT. For optional sweat
connection, install Sweat Adapter (1) (Supplied) for 3/4"
copper pipe supply line.
1. Clean the end of the supply pipe. Push the threaded
SWEAT ADAPTER (1) until it is seated against the
internal stop. Sweat the ADAPTER (1) to the pipe.
2. Install the STOP VALVE (2) to the water supply line
with the outlet positioned as required (Behind the Wall).
3. Support piping as required.
3
FLUSH OUT SUPPLY LINES; Fig. 5
1. Open STOP VALVE (1).
2. Turn on water supply to flush line of any debris or
sediment.
3. Close STOP VALVE (1) and turn off water supply line.
Fig. 3 (TOP SPUD FIXTURE ILLUSTRATED)
389mm
(15-5/16")
265mm
(10-3/8")
176mm MAX.
(6-15/16) MAX.
120mm MAX.
(4-3/4) MAX.
Fig. 4
115mm-134mm
(4-1/2 TO 5-1/4)
STOP VALVE OUTLET
Fig. 5
COUNTER-CLOCKWISE
OPENS STOP VALVE
4
ROUGH OPENING IN WALL
LEVEL
1
4
2
*FOR HOLE LOCATION OF
SUPPLY ON BACK INLET
FIXTURES, REFER TO FIXTURE
BEING INSTALLED FOR CORRECT
HEIGHT FROM FINISHED FLOOR
2
1
STOP VALVE
FILE
(3/4"NPT)
EDGES
CLEAN & SOLDER
TO ADAPTER (1)
CLOCKWISE CLOSES
STOP VALVE
1
M965643 Rev. 1.6 (11/16)