Connecting Insite To The Panel Via Rs232; Setting Up A Cloud Connection - Pyronix EURO 46 V10 Installation Manual

Hide thumbs Also See for EURO 46 V10:
Table of Contents

Advertisement

Connecting InSite to the Panel via RS232

To setup the COM port associated to 'modem', open the software, click on 'Configuration', choose
"Modem Settings" and select "RS-232" option.
Make sure that the serial COM port used by UDL is the set the same in the PC.
PLEASE NOTE: This can be found in the PC via Control Panel > Device Manager > Ports.
Make sure that in the UDL Graphic user interface, the RS-232 icon is green.
Click on 'Roving Dial Customer'.
Set 'Dial Mode' field to 'RS-232'.
Enter the Engineer Code in the 'Engineer Code' field.
Click on 'Dial'.
If connection is successful, the RS-232 icon will become blue.

Setting up a Cloud Connection

Enter the Engineer Menu.
Scroll the menu ( button) until the 'SET UP DOWNLOADING?' and press .
Choose 'Cloud' in the 'Download by' option – Press .
Make a note of your 'System ID' (to enter in the InSite software later) - Press .
Select Security level – for initial connections we recommend [0] (normal) - Press .
Create/enter a system password and take note of it - Press .
Now on the 'Poll Server' screen – select 'Yes [1]' and press .
Now on the 'UDL Password' screen – DO NOT USE – leave blank and Press .
Now on the 'Site Name' screen, this is compulsory, make sure that you take a note of it for use later in
the Insite software then press .
Now on the 'UDL Priority' screen – we recommend setting this to 'High [0]'.
PLEASE NOTE: This prevents HomeContol+ App events / notifications from disconnecting the UDL
connection.