PLEASE NOTE: EURO 46 V10 power supplies are NOT designed for use with multiple batteries
connected. System load should not exceed the panel power supply output shown above, or the
maximum load supportable by the battery for the specified backup time, as in the table shown below.
The power ratings are based on battery shown in table – but battery capable of supporting the
system load for the required time may be used without affecting these ratings.
EN50131-6:2008 Rated Output
In accordance with EN50131-6:2008, the EURO standby times and effective output currents depend on the Security Grade of the
system and how 230V mains missing fault is signalled to the Alarm Receiving Centre. Power supplies are rated in accordance with
the requirements of EN50131-6, which are related to the maximum battery size that can be accommodated in the housing and vary
according to the grade of the system in which they are installed, as per the following table:
Electrical Capability
Example Battery Model
Yuasa NP7-12
Yuasa NP17-12
EURO 46 V10 PCB Current Consumption
Quiescent
User Code and Tag Guessing
4-digit codes
6-digit codes
Disallowed codes
All codes
According to EN50131-3:2009 Annex B
According to spec of manufacturer of RFID components used
The below table specifies ATS (Alarm Transmission System) performance criteria in accordance with
the requirements of EN50136-1.
Notification Equipment
Remotely powered external sounder
Self-powered external sounder
Main communication path (ATS)
Second communication path (ATS)
8
80mA
10,000
100,000
None
1612
Grade 2 Criteria
Options
A
B
2
Optional
Optional
1
Optional
Optional
ATS 2
ATS 2
ATS 2
ATS 1
Optional
Optional
EURO 46 V10 Installation Manual
EN50131-6 Rating. Maximum Load
Grade 2
0.5A
1.2A
Environmental
Operational
Storage
Humidity
Dimensions
Small case
Metal case
Large case
PCB
EN50131 Grading
C
D
A
2
Optional
Optional
Optional
ATS 3
ATS 4
Optional
Optional
Grade 3
0.3A
0.7A
-10°C to +40°C, Certified
-20°C to +60°C
75%
250 x 297 x 82mm
Weight: 4.8kg inc. battery
390 x 305 x 100mm
Weight: 11.5kg inc. battery
170 x 90 x 30mm
3
Grade 3 Criteria
Options
B
C
D
Optional
Optional
Optional
1
Optional
Optional
ATS 4
ATS 4
ATS 5
ATS 3
Optional
Optional

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents