Access Levels

Level 1: Access by any person; for example the general public.
Level 2: User access by an operator; for example customers (systems users).
Level 3: User access by an engineer; for example an alarm company professional.
Level 4: User access by the manufacturer of the equipment.
PLEASE NOTE: Alarm, tamper and fault indications will automatically be cleared within 3 minutes. If
a user has finished viewing the information they can terminate the display instantly by pressing the
 key.

Compliance

As per EN 50131-1 the EURO 46 V10 is capable of supporting all conditions A,B and C: -
In Grades 1 & 2 I&HAS when an I&HAS or part thereof is in a set state:
A) access to the supervised premises or part thereof, via an entry/exit route, shall be prevented, or
B) opening the door to the entry/exit route shall initiate an entry procedure, or
C) indication of the set/unset status shall be provided.
In Grades 3 & 4 I&HAS when an I&HAS or part thereof is in a set state:
A) access to the supervised premises or part thereof, via an entry/exit route, shall be prevented, or
B) opening the door to the entry/exit route shall initiate an entry procedure.

Warranty

This product is sold subject to our standard warranty conditions and is warranted against defects
in workmanship for a period of two years. For further warranty information visit: www.pyronix.com/
warranty.
The declaration of conformity and further compliance documentation may be consulted at: www.
pyronix.com/product-compliance.php.
21