Power And Battery Connections - Pyronix EURO 46 V10 Installation Manual

Hide thumbs Also See for EURO 46 V10:
Table of Contents

Advertisement

Power and Battery Connections

Panel Power Supply Input
Mains Supply Voltage AC
Transformer Rating
Panel Power Supply Output
Output Voltage
Small Metal
Output Current
Large Metal
Power Supply Type A.
Battery Charging Specification
Float Voltage
Battery low voltage cut off
Recharge time
Fuses
230V Mains Fuse for mains terminals
PLEASE NOTE: Ensure that the 'battery jumper' is in the correct position for the capacity of battery
that you have connected – otherwise the panel may under-charge a large battery or over-charge and
damage a smaller battery.
12
Nominal
230V AC at 50Hz
18VA
Nominal
13.7V DC
1A Continuous
1.5A Continuous
13.8v DC
Control Panel Type
10.5v
Standby battery capacity current
<24 Hours
Standby battery capacity current
Value
T500mA H anti-surge slow blow 250V
EURO 46 V10 Installation Manual
2-6Ah 7-17Ah
Range
-15% +10%
18V at 1.0A
Range
10-15V DC
1.5A peak, during battery charging
2.0A peak, during battery charging
300mA (3Ah to 6Ah)
700mA (7Ah to 17Ah)
Type
Ceramic
EURO 46
Time
10:09 c

Hide quick links:

Advertisement

Table of Contents
loading