Input Connections

The EURO 46 V10 has options of 4k7/2k2, 4k7/4k7, 1k/1k and wide EOL ranges to choose from. The
tolerances for each of these ranges can be found in the technical specification. The 'wide' range has
no masking tolerance range. This is added on to the end of the alarm tolerance in order to create a
wider alarm tolerance range.
EURO 46 V10 panels are set to 4k7/2k2 at default and would typically used a 2k2 resistor for tamper,
4k7 resistor for alarm and finally a 6k8 resistor for mask.
PLEASE NOTE: If 'Normally Closed' (double pole) wiring is utilised, The EOL range must be set to
'4k7/2k2' and the EOL mode set to 'DR'. This can be selected in the Engineer Menu in the menu
'CHOOSE MODE'. The 'Diagnostics' on the keypad will show 6K9 when the alarm circuit is open and
2K2 when the alarm circuit is closed. It will show >22k when the tamper circuit is open.
For specific wiring instructions please refer to the installation manual provided with each component
that is being wired to the system.