Setting Parameters
Change Target Pressure
Values (p
and p
max
min
Page 22
5.2
The start value for the remaining hours can be changed. To reset / change
the start value of the countdown counter until the next motor servicing interval:
1. Unlock the code-protected parameters for the motor servicing interval
using code 222, as described under "Unlocking Code-protected Param-
eters" on page 19.
The current start value for the countdown counter flashes on the seven-
segment display.
2. Press the Info key
3. Press the Enter key
The main display reappears on the control.
The previous value is overwritten.
The changed value is set.
CAUTION
Compressor Damage
If the maximum start value (30,000 h) is set, the countdown counter stops
and the motor servicing interval function is deactivated, meaning that
urgently required servicing work may be overlooked.
Please consult BOGE Product Support prior to setting the highest value.
This parameter can be used to change the target pressure values.
)
The p
value defines the switch-off pressure of the compressor. If the
max
network pressure reaches this value during an output phase, the control
switches off the compressor automatically.
The p
value defines the switch-on pressure of the compressor. If the
min
network pressure falls below this value, the control switches the compressor
on automatically.
To change the p
1. Unlock the code-protected parameters for the target pressure values using
code 360, as described under "Unlocking Code-protected Parameters"
on page 19.
The currently valid upper target pressure value (p
seven-segment display.
2. Press the Info key
3. Press the Enter key
The currently valid lower target pressure value (p
seven-segment display.
The previous p
The changed value is set.
4. Press the Info key
Changing Individual Parameters
until the desired value is displayed.
.
and p
target pressure values:
max
min
until the desired p
.
value has been overwritten.
max
until the desired p
) flashes in the
max
value is displayed.
max
) flashes in the
min
value is displayed.
min
BOGE base control for scroll compressors