Setting Parameters
Motor Servicing Inter-
val: Restart the Counter /
Change the Start Value
BOGE base control for scroll compressors
5.2
1. Unlock the code-protected parameters for the compressor servicing inter-
val using code 111, as described under "Unlocking Code-protected
Parameters" on page 19.
 The current start value for the countdown counter flashes on the seven-
segment display.
2. Press the Info key
3. Press the Enter key
 The main display reappears on the control.
 The previous value is overwritten.
 The changed value is set.
CAUTION
Compressor Damage
If the maximum start value (21,000 h) is set, the countdown counter stops
and the compressor servicing interval function is deactivated, meaning that
urgently required servicing work may be overlooked.
 Please consult BOGE Product Support prior to setting the highest value.
This function is used to signal in advance the pending servicing of the motor.
The hours until the next motor servicing interval count down from a start value
(remaining hours). When the value reaches 0, the control outputs a mainte-
nance message. After servicing, the countdown counter must be manually
reset to the start value.
To restart and reset the countdown counter to the start value until the next
motor servicing interval:
1. Unlock the code-protected parameters for the motor servicing interval
using code 222, as described under "Unlocking Code-protected Param-
eters" on page 19.
 The current start value for the countdown counter flashes on the seven-
segment display.
2. Press the Enter key
 The main display reappears on the control.
 The servicing interval countdown counter has been reset to the start
value and restarted.
CAUTION
Compressor Damage
If the servicing interval countdown counter is not restarted, urgently
required servicing work can be overlooked.
 After all servicing work, the respective countdown counter must be
manually reset to the start value.
Changing Individual Parameters