Parameter Setting Display And Operating Procedures - Toshiba LQ300A00 Series Operation Manual

The insertion type density meter
Table of Contents

Advertisement

5.2.10

Parameter setting display and operating procedures

5:SET PARAMETERS
6:ZERO CALIBRATION
7:SPAN CALIBRATION
8:ANGLE ROTATION
Move the cursor to "5" with [→] key, and press [SET] key to select[ 5:SET PARAMETERS]
UR:UPPER RANGE
DATA:3.0
[ESC]
[SET] CHANGE
(Previous
[ESC] RETURN.
Menu)
[UP]
[DN]
LR:LOWER RANGE
DATA:0.0
[ESC]
[SET] CHANGE
(Previous
[ESC] RETURN
Menu)
[UP]
[DN]
a:DENSITY LINE SLOPE
DATA:0.0840
[ESC]
[SET] CHANGE
(Previous
[ESC] RETURN
Menu)
[UP]
[DN]
b:DENSITY INTERCEPT
DATA:0.00
[ESC]
[SET] CHANGE
(Previous
[ESC] RETURN
Menu)
[UP]
[DN]
ot:DENSTY TEST OUT.
DATA:3.0
[ESC]
[SET] CHANGE
(Previous
[ESC] RETURN
Menu)
[UP]
[DN]
[SET](Set)
[SET](Fix)
[ESC](Cancel)
The upper density measurement range (whose
current output is 20mA) is set.
[SET](Set)
[SET](Fix)
[ESC](Cancel)
The lower density measurement range (whose
current output is 4mA) is set.
[SET](Set)
[SET](Fix)
[ESC](Cancel)
The "density line slope" of the arithmetic expression for calculating the
density from the phase measurement data, etc. is set. However,
normally do not change settings here.
[SET](Set)
[SET](Fix)
[ESC](Cancel)
The "density intercept" of the arithmetic expression for calculating the
density from the phase measurement data, etc. is set. In the event that
the zero point is out of position, it is corrected through zero calibration; it is
also possible to shift the zero point by changing this coefficient. Normally,
set the value to zero.
[SET](Set)
[SET](Fix)
[ESC](Cancel)
When [2: SETTING MENU] is selected, the density output signal
and the density display are hold in the simulated values that have
been set.
In this screen, the simulated values are set in terms of "%TS".
 46 
UR:UPPER RANGE
RANGE :1.0-99.9 %TS
DATA :
[SET] SET,[ESC] CANCEL
LR:LOWER RANGE
RANGE :0.0-99.5 %TS
DATA :
[SET] SET,[ESC] CANCEL
a:DENSITY LINE SLOPE
RANGE :−0.2000−0.2000
DATA :
[SET] SET,[ESC] CANCEL
b:DENSITY INTERCEPT
RANGE :−99.99−99.99
DATA :
[SET] SET,[ESC] CANCEL
ot:DENSTY TEST OUT.
RANGE :0.0-99.9 %TS
DATA :
[SET] SET,[ESC] CANCEL