3.2 Installation Location

[NOTE]
◆ Determine an indoor installation place in accordance with the following instructions.
(1)
Choose a place that is free of vibrations and corrosive gasses, and has ample space for
maintenance.
(2)
Secure maintenance space in front, rear and above the density meter. (Refer to fig. 3.2.1)
(3)
In the case of outdoor installation, provide covering against sun.
(4)
Do not install the meter in a place where there is a possibility of leakage of flammable or
explosive gas.
(5)
Use a strength pipe, connected at both upstream and downstream sides, to securely
install the detector main body, or provide a supporting structure for the detector main
body. (Weight of this unit is shown in the external dimension list as attached.)
(6)
When the density meter is used in an application where the process fluid contains plenty
of fur or fiber, these substances may accumulate or entangle in the density meter and thus
perform the maintenance operation periodically (clean the insertion probe area).
(7)
The tank or pipe where this density meter is installed should be metal.
(8)
Install the density meter in a place where the density distribution is even. If the density
distribution is not even, manual analysis data and the indication value of the density meter
may not be the same.
(9)
Install this density meter in a piping system where bubbles are not found, and fluid does
not empty itself, and also sedimentation and accumulation of materials does not occur.
 19 
6 F 8 A 0 7 8 7