Statistics; Parameter Settings - INVT iMars Operation Manual

Grid-tied solar inverter
Hide thumbs Also See for iMars:
Table of Contents

Advertisement

iMars grid-tied solar inverters
through the historical information, press "ESC" to return. The number on the upper right corner of
the first row is the number of historical record, the 2
and time when fault occurred or restored, and the 3
rd
code. When the 3
row displays in inverse color, it indicates fault occurred, otherwise it is fault
restored.

6.4.3 Statistics

Press "
" and "
" in the main interface to select "Statistics", and then press "ENT" to view the
parameters which is shown in Figure 6.6.
The information in table 6-2 can be viewed in the statistical menu.
Table 6-2 Statistic information
Content
Lifetime
Time statistics
Day statistics
Latest 7 days
Latest 1 month
Latest 30 days
Latest 1 year

6.4.4 Parameter settings

Press "
" and "
" in the main interface to select "Setup Menu", and then press "ENT" to view
the parameters which is shown in Figure 6.7.
S t a t i s t i c a l M e n u
L i f e t i m e
T o d a y
Figure 6.6 Statistic information
Total operation time, total power produced, total power saved, total CO
reduction in lifetime
Total power produced, total power saved, peak power and total CO
reduction in statistical time
Total power produced, total power saved, peak power and total CO
reduction in current day
Total power produced, total power saved and total CO
latest 7 days
Total power produced, total power saved and total CO
latest 1 month
Total power produced, total power saved and total CO
latest 30 days
Total power produced, total power saved and total CO
latest 1 year
nd
row (as shown in Fig 6.5) displays the date
rd
row displays detailed information of fault
Detailed
39
Display panel
2
2
2
reduction in
2
reduction in
2
reduction in
2
reduction in
2

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the iMars and is the answer not in the manual?

Questions and answers

razafinimanana andre joseph
April 16, 2025

Hi, i've got a new INVT XG30KTR from China and i cant sart it , how i have to do , do i need something eslse like USB or anything else with it

2 comments:
Mr. Anderson
April 16, 2025

To start the INVT XG30KTR inverter:

1. Disconnect the DC and AC side circuit breakers before wiring.
2. Wait at least 5 minutes after disconnecting before performing any wiring or checks.
3. Ensure the inverter is reliably grounded.
4. Power on the inverter using DC input.
5. On first startup or after restoring factory settings, select the country on the LCD screen.

You do not need a USB to start the inverter. All initial setup is done using the LCD screen and buttons.

This answer is automatically generated

razafinimanana andre joseph
April 21, 2025

@Mr. Anderson

User image 680639160b085
razafinimanana andre joseph
April 28, 2025

je vous envoie l'image du LCD

User image 680f47896d5f7
razafinimanana andre joseph
April 28, 2025

voici l'autre image

User image 680f47af59e23
razafinimanana andre joseph
April 28, 2025

Bonjour, ça ne marche pas toujours voila ce que le LCD montre : RUNNING ERROR; GRID EN 50549; FAULT 31-03; F 31-03 , je vous met en photo l'ecran

User image 680f46d285a77
1 comments:
Mr. Anderson
May 15, 2025

The error message "RUNNING ERROR; GRID EN 50549; FAULT 31-03; F 31-03" refers to a grid-related fault according to the EN 50549 standard. It indicates the inverter has detected a fault condition related to grid parameters that do not comply with the required standard, such as voltage, frequency, or other grid quality issues. The specific fault code "31-03" is not detailed in the provided context, so the exact cause cannot be determined.

This answer is automatically generated