APPLICATION AND OPERATION (CONT'D)
Do NOT handle pump with wet hands or when
standing in water or on a damp surface when the unit is operating
or fails to operate. ALWAYS disconnect pump power cord from power
source before handling.
NE PAS manipuler la pompe avec les mains
humides ou debout dans l'eau ou sur une surface humide lorsque
l'appareil fonctionne ou ne fonctionne pas correctement. TOUJOURS
débrancher le cordon d'alimentation de la pompe de la source
d'alimentation avant toute manipulation.
6. Plug the power cord into a grounded 115 volt GFCI power outlet.
The pump will start operating as soon as the power cord is
plugged into the power outlet.
7. The pump will remove water down to 3/8 in. above the hard
surface the pump was placed on.
8. The pump should be turned off once the water level reaches the
3/8 in. mark.
MAINTENANCE/TROUBLESHOOTING
ALWAYS disconnect electric supply before
attempting to install, service, relocate, or perform any maintenance.
Failure to do so COULD result in fatal electrical shock.
TOUJOURS couper le courant avant d'essayer
d'installer, de réparer, de déplacer ou de faire tout entretien. Le
non-respect de ces instructions POURRAIT entraîner une décharge
électrique mortelle.
There are no internal servicable parts. If pump should fail to operate,
perform the following troubleshooting guidelines, contact Customer
Support at 1-800-237-0987, or replace the pump:
Figure 1 - Water Level
4
Disassembly of the motor housing or alteration
of the power cord COULD result in fatal electrical shock, and void
warranty.
Démonter le boîtier du moteur ou modifier le
cordon d'alimentation POURRAIT entraîner une décharge électrique
mortelle et annuler la garantie.
1. To verify pump is operating correctly:
a. Disconnect pump from power source.
b. Disconnect discharge hose from pump.
c. Immerse pump in a bucket or tub of water.
d. Plug power cord into a grounded 115 volt GFCI power outlet.
If pump operates correctly, proceed to next step. If pump
does NOT operate, unplug power cord and proceed to step
#3 in this section.
2. To verify discharge hose is free from a blockage:
Connect hose to another water source such as a faucet. If
water is restricted, verify discharge hose is unwound. Remove
all kinks, bends, or obstructions in hose.
Verify pumping height does NOT exceed 20 feet
(See Figure 1). If pumping height is greater than 20 feet, this pump will
NOT work.
3. Periodic cleaning of pump is required to maintain performance of
the pump. Follow the cleaning steps listed below:
a. Unplug the power cord.
b. Remove the 4 screws in the bottom of the base.
c. Remove the base and inlet plate.
d. Remove the debris and make sure the impeller turns freely.
e. Reinstall inlet plate, base, and screws.