Operating Instructions and Parts Manual
SPECIFICATIONS
POWER SUPPLY
REQUIREMENTS
120 V, 60 Hz
MOTOR
Single Phase, Dielectric Oil Filled
HORSEPOWER
1/2 HP ............ Sewage (RPP50, SEL50, WCS50T)
LIQUID TEMPERATURE
40° F - 120° F
CIRCUIT REQUIREMENTS
15 A (minimum)
DIMENSIONS
14 in. high x 12 in. base (RPP50)
13-1/2 in. high x 11 in. base (SEL50, EFL50)
16-5/8 in. high x 9-5/8 in. base (WCS50T)
ON LEVEL (FACTORY SET)
Approximately 16. in. (RPP50)
Approximately 17 in. (SEL50, EFL50)
Approximately 19 in. (WCS50T)
OFF LEVEL (FACTORY SET)
Approximately 7.5 in. (RPP50)
Approximately 7 in. (SEL50, EFL50)
Approximately 10.5 in. (WCS50T)
CONSTRUCTION
Cast Iron (RPP50, WCS50T)
MOTOR HOUSING
Reinforced Thermoplastic (SEL50, EFL50)
VOLUTE
Cast Iron (RPP50, WCS50T)
Cast Iron
IMPELLER
Glass Reinforced Thermoplastic
SHAFT
Steel
DISCHARGE
2 in. NPT
PERFORMANCE
Model
HP Discharge Head
RPP50
1/2
SEL50
1/2
WCS50T
1/2
EFL50
1/2
© 2018, WAYNE/Scott Fetzer Company.
Effluent (EFL50)
Reinforced Thermoplastic
(SEL50, EFL50)
Glass Reinforced Thermoplastic
0 ft
5 ft
10 ft
Gal / hr
6200
4800
3240
Gal / hr
10000
9000
7200
Gal / hr
10000
9600
8000
Gal / hr
10000
9000
7200
Please read and save these instructions. Read carefully before attempting to assemble, install,
operate or maintain the product described. Protect yourself and others by observing all safety
information. Failure to comply with instructions could result in personal injury and/or property
damage! Retain instructions for future reference.
15 ft
20 ft
1500
-
5000
2000
3300
-
5000
2000
Intended for Indoor Use Only
www.waynepumps.com
Sewage/Effluent Pumps
Sewage/Effluent
RPP50
Sewage- SEL50
Effluent- EFL50
WCS50T
610001-001 B 08/18