7. COMMUNICATION THAT DO NOT REQUIRE
THE SEQUENCE PROGRAM
7.1.19
For the sequence program to be operated from the client the Program Invocation for the main
sequence program domain is defined.
In the AJ71PB96F/A1SJ71PB96F only the Program Invocation can be allocated to the main sequence
program domain. The sub sequence program cannot be allocated.
PI status change
Status after execution
[Parameters required by the client]
• Password
• Access Group
• Access Right
• Reusable

Execution program definition (Create Program Invocation: Server)

NON-EXISTENT
IDLE
The AJ71PB96F/A1SJ71PB96F does not have an access protection function. Always specify
FFh.
Item
Password
The AJ71PB96F/A1SJ71PB96F does not have an access protection function. Always specify
FFh.
Item
Access Group
The AJ71PB96F/A1SJ71PB96F does not have an access protection function. Always specify
FFFFh.
Item
Access Right
Always specify True so that the sequence program can be run again after being stopped.
Item
Reusable
PI status before execution
IDLE
×
Value
FFh
Value
FFh
Value
FFFFh
Value
True = FFh
7-23
MELSEC-A
RUNNING
STOPPED
×
×