6. COMMUNICATIONS THAT REQUIRE THE SEQUENCE PROGRAM
Explanation
*1 For details regarding the error codes, refer to the Appendix.
*2 Always set to 0 when the access mode is index.
*3 This displays whether or not the OD was referenced when setting the receive data in the
receive data area.
Referenced -------------------------------------------------------------- > 0000h
Not referenced ---------------------------------------------------------- > FFFFh
The OD is not referenced for the respond to open connection (/0), broadcast, or multicast
connection.
*4 The variable type (the following values are set)
Simple Variable --------------------------------------------------------- > 0007h
Array----------------------------------------------------------------------- > 0008h
Record -------------------------------------------------------------------- > 0009h
When OD flag = FFFFh----------------------------------------------- > FFFFh
Explanation
*5 Number of elements (the following values are set).
Simple Variable --------------------------------------------------------- > 0001h
Array, Record ----------------------------------------------------------- > number of elements
When OD flag = FFFFh----------------------------------------------- > 0001h
*6 Data type (the following values are set).
Truth value (Boolean) ------------------------------------------------- > 0001h
Integer with code (Integer8) ----------------------------------------- > 0002h
Integer with code (Integer16)---------------------------------------- > 0003h
Integer with code (Integer32)---------------------------------------- > 0004h
Integer (Unsigned8) --------------------------------------------------- > 0005h
Integer (Unsigned16)-------------------------------------------------- > 0006h
Integer (Unsigned32)-------------------------------------------------- > 0007h
Floating point (FloatingPoint)---------------------------------------- > 0008h
Character string (VisibleString) ------------------------------------- > 0009h
Octet string (OctetString)--------------------------------------------- > 000Ah
Bit string (BitString) ---------------------------------------------------- > 000Eh
When OD flag = FFFFh----------------------------------------------- > FFFFh
*7 Data length (byte) (the following values are set).
Array, Record -----> This shows the byte value for the data length of the data in one element.
Simple Variable ---> This shows the byte value for the data length.
When OD flag = FFFFh--------> This shows the byte value for the data length.
*8 Data length (word) (the following values are set).
Array, Record -----> This shows the word value for the data length.
Simple Variable ---> This shows the word value for the data length
When OD flag = FFFFh--------> This shows the word value for the data length.
*9 Buffer memory
The buffer memory address for reading the element is set.